The Measurable difference.

Power Analyzer

Mixed Signal Power Analyzer

DEWETRON’s Mixed Signal Power Analyzers are the best solution
for high-performance power analysis.

  • 0.03 % measurement error
  • Up to 10 MS/s @ 18-bit sampling rate
  • Up to 16 different power phases
  • Raw data recording
  • Safety category CAT IV

Download Power Analyzer Datasheet

   18-bit A/D Conversion   10 MS/s/ch        Icon for 1000 V    Icon for direct input with 24 ampere    Icon raw data recording    CAT IV Safety Category    Icon for IEC 61000-4    icon for 6P6W

Accuracy

Thanks to the low measurement error of 0.03 %, the Power Analyzer achieves very high accuracy, even with low range utilization. Precision accuracy is guaranteed through the whole analysis.

Diagram of Power Accuracy versus Frequency shows extremly little Measurement Error

High Dynamic Range

Fast acquisition rates of up to 10 MS/s and 18-bit A/D conversion, as well as the best linearity of the signal conditioning, offers the highest dynamic performance in the whole input range –  up to 1000 V and 20 A with the highest possible accuracy for all your dynamic applications.

Up to 10 MS/s/ch and high dynamic range guarantee data integrity.

Multi-Power Analyzer

A DEWETRON Power Analyzer is the solution for the analysis of several motors, converters or complete drive trains simultaneously. Up to 16 different power phases and the capability for calculation of power parameters even for polyphase motors (up to 9 phases) turns the Power Analyzer into a multi-power analyzer.

OXYGEN Recording with high Data Rates up to 1 GB/s

Raw Data Recording /
Waveform Recording

Waveform data, mixed signals and power analysis? A DEWETRON Power Analyzer combines all. Reliable gapless raw data recording of any analog or digital signal and high performance power calculation of several power groups simultaneously.

 

Icon for 1 TB Storage Capacity   Raw Data Recording

Mixed-signals

Our Power Analyzers are also mixed-signal recorders, that means you only need ONE system for all inputs:

  • Modular and Mixed Signal inputs
  • Isolated high voltage & current inputs
  • High-performance auxiliary inputs (e.g. torque, speed, vibration)
  • CAN interface with input and output function
  • EtherCAT and XCP, SCPI over Ethernet
  • High number of mid-speed inputs for low dynamic signals (e.g. temperature)
  • PTP, GPS, IRIG synchronization
  • Counter

Modularity and Expandability

Do you need more input channels? No problem, the Power Analyzers can be extended in many ways. Just add another TRION™ module, if there is a free slot or use a TRIONet for a higher channel count. Data is automatically synchronized across all channels.

 

If you need more input channels, you can easily expand the Power Analyzer with a DEWE2 Front-end chassis for a higher channel count or add static inputs by using CPAD or EPAD modules.

Integrated Transducer Supply

The Power Analyzers provide integrated (redundant) power supply for 8 current transducers. The integrated transducer power supply enables the engineer to relinquish an additional supply box and connect the transducers directly to the Power Analyzer.

 

Most of the common sensors with ±15 V or +9 V are compatible, also demanding ones (like zero-flux transducers) can be powered thanks to the superior power supply.

DEWE2-PA7 with current transducers
Testbed with DEWE2-PA7

Testbed interfaces

Smart interface technology makes it easy to integrate a Power Analyzer into automation systems and testbed environments while it is guaranteeing reliable data transmission, easy to use remote control and remote configuration through TCP/IP based protocols in compliance with standardized protocols (e.g. ASAM) and file formats.

Icon for Gigabit Ethernet Icon for USB 3.0 icon for EtherCAT Icon for SCPI Icon for CAN Icon for XCP Icon for ASAM

OXYGEN

OXYGEN Measurement Software seamlessly integrates data being transmitted through multiple, totally synchronized signals into calculations for power analysis.

 

  • Analysis of 1-9 phase power systems (1P2W, 2V2A, 3P3W, 3P4W, 6P6W, …)
  • Several power systems are logically summarized into power groups
  • Gapless cycle-by-cycle calculation, no blind spots

ISO 17025 Calibration

Our Power Analyzers are optionally supplied with an EN ISO/IEC17025 certification. Calibration and adjustment are done in the accredited calibration laboratory at the DEWETRON headquarters in Graz/Austria.

 

Find out more about DEWETRON’s accredited calibration lab.

Compliance to industry standards

Analysis of harmonics, interharmonics, and higher frequencies as well as voltage fluctuations and flicker emissions are done according to industry standard.

  • IEC 61000-4-7
  • IEC 61000-4-15
  • IEC 61400-21

 

DEWETRON provides with CAT IV the highest safety class for Power Analyzers on the market.

Compliance to industry standards like IEC 61000-4-7

Whitepaper Effcient Analyzation of Dynamic Electric Vehicles

Comparison of 2 Power Analyzer Models

Thanks to DEWETRON’s modular approach, any TRION/TRION(3) based data acquisition hardware can become a power analyzer. You can choose between two types of power modules with 8 input channels, each with 18-bit resolution. Because of the unique modularity, 4 channels can be equipped with different user-exchangeable sub-modules for direct current or voltage measurement. So almost any kind of voltage or current sensor can be connected to a DEWETRON power analyzer. In the following comparison, you see DEWETRON’s dedicated power analyzer chassis.

DEWE2-PA7 Power Analyzer with hand DEWE3-PA8 highspeed Power Analyzer with hand
Model type DEWE2-PA7 DEWE3-PA8
Number of different power phases Up to 12 Up to 16
Sampling rate 2 MS/s/ch 10 MS/s/ch
Resolution 18-bit A/D 18-bit A/D
Measurement error of analog input U, I
0.03 % 0.03 %
Reading error of power measurement
0.04 % 0.04 %
Dimensions 4 u, 19” rack-mount 5 u, 19” rack-mount
Display size 9” 11.6”
Slots for TRION™ modules 7 8
Integrated transducer supply Up to 8 8 redundant
Datasheet download DEWE2-PA7 DEWE3-PA8
BACK TO TOP

DO YOU HAVE A QUESTION?

Kontakt-Formular

contact contact